3S-4S PCM/BMS
Home > 3S-4S PCM/BMS
LT-4S/5S-3566 4S BMS 5A-30A
4S 12.8V 14.8V BMS
Working Amps available in 5A to 30A
Over charge protection
Over discharge protection
Over current protection
Short circuit protection
Temperature protection (optional)
Blancing (optional)
- Product Detail
- Inquiry
Specification
No. | Tested Item | Criterion | |||||||||||
1 | Voltage | Charging Voltage | DC:16.8V CC/CV | ||||||||||
Blance Volatage for single cell | 45±5 mA | ||||||||||||
2 | Current | Blance Current for single cell | 45±5 mA | ||||||||||
Current consumption | ≤30μA | ||||||||||||
Max continuous charging current | 5A-30A | ||||||||||||
Max continuous discharging current | 5A-30A | ||||||||||||
3 | Over Charge Protection | Over charge detection voltage | 3.75±0.05V | ||||||||||
Over charge detection delay time | 300-500ms | ||||||||||||
Over charge release voltage | 3.6±0.05V | ||||||||||||
4 | Over Discharge Protection | Over discharge detection voltage | 2.1±0.08V | ||||||||||
Over discharge detection delay time | 1-100ms | ||||||||||||
Over discharge release voltage | 2.5±0.10V | ||||||||||||
5 | Over Current Protection | Over current detection current-Charging | 1.5 times | ||||||||||
Over current detection current-Discharging | 3 times | ||||||||||||
Release condition | Cut load | ||||||||||||
Over current detection delay time | 1-40ms | ||||||||||||
6 | Short Circuit Protection | Detection condition | Exterior short circuit | ||||||||||
Release condition | Cut short circuit | ||||||||||||
Short circuit detection delay time | 250us | ||||||||||||
7 | Temperature Protection | Temperature Protection | 50℃ 75℃ cutoff | ||||||||||
8 | Interior Resistance | Main loop electrify resistance | VC=3.6V,RDS≤60mΩ | ||||||||||
9 | Temperature | Operating Temperature | -45℃ --+65℃ | ||||||||||
Storage Temperature | -45℃ -- +85℃ |